Test Information

 ATHENA CANNOT ACCEPT CSF THAT HAS BEEN COLLECTED IN A POLYSTYRENE TUBE!  The proteins being tested are damaged and greatly reduced when collected or stored in a non-polypropylene tube.  If a sample is stored in polypropylene, sample can be thawed and realiquoted two cycles.  

Collect


Polypropylene tube ONLY

Aliquot Containers - Lab/Outreach Use Only

Preferred Draw Volume

2 mL

Minimum Draw Volume

0.5 mL

Other Acceptable Containers

Polypropylene Transfer Tube ONLY

Unacceptable Conditions

Received in any other container but polypropylene

Collection Comments

Call the send out lab at Send Outs: 317-491-6805 for instructions on special collection container required. CSF collection vials in the IU Health lumbar puncture trays are polystyrene. Provider or person collecting CSF must immediatley place sample into any polypropylene tube type upon collection! (glass and polystyrene are not acceptable). Ship samples to IUHPL FROZEN Monday thru Thursday. Polypropylene Transfer Tubes are available in the send out lab. https://www.athenadiagnostics.com/view-full-catalog/admark-phospho-tau-total-tau-a-beta42analysis-and-interpcsfsymptomatic1

Storage/Transport Temperature

Frozen CSF in Polypropylene tube ONLY

Stability (from collection to initiation)

Room Temp: 72 Hours, Refrigerated: 21 days, Frozen: 4 months

Special Handling

LAB: CRITICAL USE POLYPROPYLENE TUBE

Ordering Recommendations

Correlates levels of Phosphorylated-Tau protein, Total-Tau protein and AB42 peptide in CSF.

Methodology

ELISA

Reported

8-15 days

Performing Lab

Send Outs

Referral Lab

Athena Diagnostics

Synonyms

  • 177
  • Admark Phospho Tau
  • TAU/AB42
  • CSF TAU
  • TAU
  • ATHENA 177

Reference Interval

By Report

Clinical Interpretation

Correlation of levels of markers of Phosphorylated-Tau, Total-Tau, and Ab42

CPT Codes

83520 (x3)

Test Code (Outreach Synonym)

177

Catalog Code

6134376115
Collection

Test Information

 ATHENA CANNOT ACCEPT CSF THAT HAS BEEN COLLECTED IN A POLYSTYRENE TUBE!  The proteins being tested are damaged and greatly reduced when collected or stored in a non-polypropylene tube.  If a sample is stored in polypropylene, sample can be thawed and realiquoted two cycles.  

Collect


Polypropylene tube ONLY

Aliquot Containers - Lab/Outreach Use Only

Preferred Draw Volume

2 mL

Minimum Draw Volume

0.5 mL

Other Acceptable Containers

Polypropylene Transfer Tube ONLY

Unacceptable Conditions

Received in any other container but polypropylene

Collection Comments

Call the send out lab at Send Outs: 317-491-6805 for instructions on special collection container required. CSF collection vials in the IU Health lumbar puncture trays are polystyrene. Provider or person collecting CSF must immediatley place sample into any polypropylene tube type upon collection! (glass and polystyrene are not acceptable). Ship samples to IUHPL FROZEN Monday thru Thursday. Polypropylene Transfer Tubes are available in the send out lab. https://www.athenadiagnostics.com/view-full-catalog/admark-phospho-tau-total-tau-a-beta42analysis-and-interpcsfsymptomatic1

Storage/Transport Temperature

Frozen CSF in Polypropylene tube ONLY

Stability (from collection to initiation)

Room Temp: 72 Hours, Refrigerated: 21 days, Frozen: 4 months

Special Handling

LAB: CRITICAL USE POLYPROPYLENE TUBE
Ordering

Ordering Recommendations

Correlates levels of Phosphorylated-Tau protein, Total-Tau protein and AB42 peptide in CSF.

Methodology

ELISA

Reported

8-15 days

Performing Lab

Send Outs

Referral Lab

Athena Diagnostics

Synonyms

  • 177
  • Admark Phospho Tau
  • TAU/AB42
  • CSF TAU
  • TAU
  • ATHENA 177
Result Interpretation

Reference Interval

By Report

Clinical Interpretation

Correlation of levels of markers of Phosphorylated-Tau, Total-Tau, and Ab42
Additional Information

CPT Codes

83520 (x3)

Test Code (Outreach Synonym)

177

Catalog Code

6134376115