Collect


Blood, Royal Blue (No additive) - Red band

Aliquot Containers - Lab/Outreach Use Only

Preferred Draw Volume

3 mL

Minimum Draw Volume

2 mL

Other Acceptable Containers

Royal blue (EDTA), or Royal blue (NaHep).

Unacceptable Conditions

Separator tubes. Specimens that are not separated from the red cells, or clot, within 6 hours.  Specimens collected in containers other than specified. Specimens transported in container other than specified

Collection Comments

Allow Royal Blue Red Band tube to sit for 30 minutes to form clot. Spin for 10 minutes at 1100-1300 g in a swing bucket unit or 15 minutes in a fixed angle to separate cells from serum. Remember to properly label tube with patient name, DOB, test and collect date. Do not collect in orange top tube. Transfer 2 mL serum to an ARUP Trace Element (Metal Free) aliquot tube (ARUP supply #43116). (Minimum 0.5 mL) . Separate serum from cells ASAP or within 2 hours of collection. http://ltd.aruplab.com/Tests/Pub/0025037 http://ltd.aruplab.com/Tests/Pdf/445

Storage/Transport Temperature

Refrigerated

Stability (from collection to initiation)

Ambient: Indefinitely; Refrigerated: Indefinitely; Frozen: Indefinitely

Special Handling

Royal Blue Red Band - Metal Free Aliquot

Ordering Recommendations

May be used in the assessment of occupational exposure or toxic ingestion. http://ltd.aruplab.com/Tests/Pub/0025037

Performed

Sunday - Saturday

Methodology

Quantitative Inductively Coupled Plasma-Mass Spectrometry

Reported

2-4 days

Performing Lab

Send Outs

Referral Lab

ARUP Laboratories

Synonyms

  • 10437
  • Cobalt

Reference Interval

By Report

Clinical Interpretation

Serum cobalt levels can be used in the assessment of occupational exposure or toxic ingestion and is the preferred specimen type for evaluating metal ion release from metal-on-metal joint arthroplasty. See ARUP website for details. NOTE: Elevated results from noncertified trace element-free tubes may be due to contamination.  Interpretation and Reference Range

CPT Codes

83018

LOINC Codes

  NAME LOINC
Order Cobalt Level, Serum/Plasma 5627-5

Test Code (Outreach Synonym)

10437

Catalog Code

6570059915
Collection

Collect


Blood, Royal Blue (No additive) - Red band

Aliquot Containers - Lab/Outreach Use Only

Preferred Draw Volume

3 mL

Minimum Draw Volume

2 mL

Other Acceptable Containers

Royal blue (EDTA), or Royal blue (NaHep).

Unacceptable Conditions

Separator tubes. Specimens that are not separated from the red cells, or clot, within 6 hours.  Specimens collected in containers other than specified. Specimens transported in container other than specified

Collection Comments

Allow Royal Blue Red Band tube to sit for 30 minutes to form clot. Spin for 10 minutes at 1100-1300 g in a swing bucket unit or 15 minutes in a fixed angle to separate cells from serum. Remember to properly label tube with patient name, DOB, test and collect date. Do not collect in orange top tube. Transfer 2 mL serum to an ARUP Trace Element (Metal Free) aliquot tube (ARUP supply #43116). (Minimum 0.5 mL) . Separate serum from cells ASAP or within 2 hours of collection. http://ltd.aruplab.com/Tests/Pub/0025037 http://ltd.aruplab.com/Tests/Pdf/445

Storage/Transport Temperature

Refrigerated

Stability (from collection to initiation)

Ambient: Indefinitely; Refrigerated: Indefinitely; Frozen: Indefinitely

Special Handling

Royal Blue Red Band - Metal Free Aliquot
Ordering

Ordering Recommendations

May be used in the assessment of occupational exposure or toxic ingestion. http://ltd.aruplab.com/Tests/Pub/0025037

Performed

Sunday - Saturday

Methodology

Quantitative Inductively Coupled Plasma-Mass Spectrometry

Reported

2-4 days

Performing Lab

Send Outs

Referral Lab

ARUP Laboratories

Synonyms

  • 10437
  • Cobalt
Result Interpretation

Reference Interval

By Report

Clinical Interpretation

Serum cobalt levels can be used in the assessment of occupational exposure or toxic ingestion and is the preferred specimen type for evaluating metal ion release from metal-on-metal joint arthroplasty. See ARUP website for details. NOTE: Elevated results from noncertified trace element-free tubes may be due to contamination.  Interpretation and Reference Range
Additional Information

CPT Codes

83018

LOINC Codes

  NAME LOINC
Order Cobalt Level, Serum/Plasma 5627-5

Test Code (Outreach Synonym)

10437

Catalog Code

6570059915