EPIC Lab Number

LAB4773

Patient Preparation

Diet, medication, and nutritional supplements may introduce interfering substances. Patients should be encouraged to discontinue nutritional supplements, vitamins, minerals, non-essential over-the-counter medications (upon the advice of their physician), and avoid shellfish and seafood for 48 to 72 hours.

Collect

Royal blue (K2EDTA) or Royal blue (NaHep).

Additional Requirements

Collect: Dark Blue Lav (Vacutainer Na2 EDTA)
Auto Lab Accepts:
Laboratory Alliance of Central New York, LLC

Unacceptable Conditions

Specimens collected in tubes other than Royal blue (K2EDTA) or Royal blue (NaHep). Specimens transported in containers other than Royal blue (K2EDTA) or Royal blue (NaHep) or Trace Element-Free Transport Tube. Clotted specimens.

Specimen Preparation

Transport 3 or 6 mL whole blood in the original collection tube. (Min: 0.5 mL)

Ordering Recommendations

Useful in the assessment of recent exposure to arsenic, mercury, and lead. For chronic exposure or the determination of arsenic species, refer to Heavy Metals Panel 4, Urine with Reflex to Arsenic Fractionation (0020572). For occupational exposure, consider Lead, Industrial Exposure Panel, Adults (0025016) and/or Cadmium Exposure Panel - OSHA (0025013).

Storage/Transport Temperature

Room temperature. Also acceptable: Refrigerated.

Stability (from collection to initiation)

Ambient: 1 week; Refrigerated: 1 week; Frozen: Unacceptable

Performed

Sun-Sat

Reported

1-4 days

Remarks

Trace Elements requisition form may be required (ARUP form #32990).

Notes

Mercury is volatile; concentration may decrease over time. If the specimen is drawn and stored in the appropriate container, the arsenic and lead values do not change with time.

Section

Reference Laboratory-ARUP Laboratories

Methodology

Quantitative Inductively Coupled Plasma-Mass Spectrometry (ICP-MS)

Synonyms

  • mercury blood level
  • Pb
  • arsenic blood level
  • AS
  • Hg
  • Lead
  • lead blood level
  • Mercury
  • Arsenic

Reference Interval

Components
Reference Interval
Lead, Blood (Venous)
Age
Reference Interval (µg/dL)
0-5 yearsLess than or equal to 3.4
6 years or aboveLess than or equal to 4.9

Arsenic BloodLess than or equal to 12.0 µg/L
Mercury BloodLess than or equal to 10.0 µg/L

Interpretive Data

Refer to report.

ARUP Test Code

0099470

LOINC

  • 77307-7
  • 5583-0
  • 5685-3

CPT Codes

82175; 83655; 83825
Test Information

EPIC Lab Number

LAB4773

Patient Preparation

Diet, medication, and nutritional supplements may introduce interfering substances. Patients should be encouraged to discontinue nutritional supplements, vitamins, minerals, non-essential over-the-counter medications (upon the advice of their physician), and avoid shellfish and seafood for 48 to 72 hours.

Collect

Royal blue (K2EDTA) or Royal blue (NaHep).

Additional Requirements

Collect: Dark Blue Lav (Vacutainer Na2 EDTA)
Auto Lab Accepts:
Laboratory Alliance of Central New York, LLC

Unacceptable Conditions

Specimens collected in tubes other than Royal blue (K2EDTA) or Royal blue (NaHep). Specimens transported in containers other than Royal blue (K2EDTA) or Royal blue (NaHep) or Trace Element-Free Transport Tube. Clotted specimens.

Specimen Preparation

Transport 3 or 6 mL whole blood in the original collection tube. (Min: 0.5 mL)

Ordering Recommendations

Useful in the assessment of recent exposure to arsenic, mercury, and lead. For chronic exposure or the determination of arsenic species, refer to Heavy Metals Panel 4, Urine with Reflex to Arsenic Fractionation (0020572). For occupational exposure, consider Lead, Industrial Exposure Panel, Adults (0025016) and/or Cadmium Exposure Panel - OSHA (0025013).

Storage/Transport Temperature

Room temperature. Also acceptable: Refrigerated.

Stability (from collection to initiation)

Ambient: 1 week; Refrigerated: 1 week; Frozen: Unacceptable

Performed

Sun-Sat

Reported

1-4 days

Remarks

Trace Elements requisition form may be required (ARUP form #32990).

Notes

Mercury is volatile; concentration may decrease over time. If the specimen is drawn and stored in the appropriate container, the arsenic and lead values do not change with time.

Section

Reference Laboratory-ARUP Laboratories

Methodology

Quantitative Inductively Coupled Plasma-Mass Spectrometry (ICP-MS)

Synonyms

  • mercury blood level
  • Pb
  • arsenic blood level
  • AS
  • Hg
  • Lead
  • lead blood level
  • Mercury
  • Arsenic

Reference Interval

Components
Reference Interval
Lead, Blood (Venous)
Age
Reference Interval (µg/dL)
0-5 yearsLess than or equal to 3.4
6 years or aboveLess than or equal to 4.9

Arsenic BloodLess than or equal to 12.0 µg/L
Mercury BloodLess than or equal to 10.0 µg/L

Interpretive Data

Refer to report.

ARUP Test Code

0099470

LOINC

  • 77307-7
  • 5583-0
  • 5685-3

CPT Codes

82175; 83655; 83825