Diet, medication, and nutritional supplements may introduce interfering substances. Patient should be encouraged to discontinue nutritional supplements, vitamins, minerals, and non-essential over-the-counter medications (upon the advice of their physician) and avoid shellfish and seafood for 48 to 72 hours.
Collect
Royal blue (K2EDTA) or royal blue (NaHep).
Additional Requirements
Do not spin specimen.
Collect: Dark Blue / Lav Strip
Auto Lab Accepts:
Unacceptable Conditions
Specimens collected in tubes other than royal blue (K2EDTA) or royal blue (NaHep).
Specimens transported in containers other than royal blue (K2EDTA) or royal blue (NaHep) tube or trace element-free transport tube. Clotted specimens.
Specimen Preparation
Transport 3 or 6 mL whole blood in the original collection tube. (Min: 0.5 mL)
Ordering Recommendations
May be useful for the detection of recent (<24 hours after exposure) and/or large dose arsenic exposures. For acute or chronic exposure, Arsenic, Urine with Reflex to Fractionated (0025000) is preferred.
Elevated results may be due to skin or collection-related contamination, including the use of a noncertified metal-free collection/transport tube. If contamination concerns exist due to elevated levels of blood arsenic, confirmation with a second specimen collected in a certified metal-free tube is recommended.
Potentially toxic ranges for blood arsenic: Greater than or equal to 600 µg/L.
Blood arsenic is for the detection of recent exposure poisoning only. Blood arsenic levels in healthy subjects vary considerably with exposure to arsenic in the diet and the environment. A 24-hour urine arsenic is useful for the detection of chronic exposure.
ARUP Test Code
0099045
LOINC
5583-0
CPT Codes
82175
Test Information
EPIC Lab Number
LAB5574
Patient Preparation
Diet, medication, and nutritional supplements may introduce interfering substances. Patient should be encouraged to discontinue nutritional supplements, vitamins, minerals, and non-essential over-the-counter medications (upon the advice of their physician) and avoid shellfish and seafood for 48 to 72 hours.
Collect
Royal blue (K2EDTA) or royal blue (NaHep).
Additional Requirements
Do not spin specimen.
Collect: Dark Blue / Lav Strip
Auto Lab Accepts:
Unacceptable Conditions
Specimens collected in tubes other than royal blue (K2EDTA) or royal blue (NaHep).
Specimens transported in containers other than royal blue (K2EDTA) or royal blue (NaHep) tube or trace element-free transport tube. Clotted specimens.
Specimen Preparation
Transport 3 or 6 mL whole blood in the original collection tube. (Min: 0.5 mL)
Ordering Recommendations
May be useful for the detection of recent (<24 hours after exposure) and/or large dose arsenic exposures. For acute or chronic exposure, Arsenic, Urine with Reflex to Fractionated (0025000) is preferred.
Elevated results may be due to skin or collection-related contamination, including the use of a noncertified metal-free collection/transport tube. If contamination concerns exist due to elevated levels of blood arsenic, confirmation with a second specimen collected in a certified metal-free tube is recommended.
Potentially toxic ranges for blood arsenic: Greater than or equal to 600 µg/L.
Blood arsenic is for the detection of recent exposure poisoning only. Blood arsenic levels in healthy subjects vary considerably with exposure to arsenic in the diet and the environment. A 24-hour urine arsenic is useful for the detection of chronic exposure.