Collect

Collect in light blue top tubes (sodium citrate anticoagulant).
All routine coagulation testing (PT/INR, PTT, FIB, D-Dimer, Xa-Lovenox, Xa-Unfractionated, DTIBI, ATIII) may be collected in the same tube.

One FULL 1.8 mL OR 2.7 mL tube.











 


Note: For all coagulation testing, ensure tubes are sufficiently filled. Refer to the guide below.

Unacceptable Conditions

Inadequately filled specimens; hemolyzed/clotted specimens; specimens greater than 4 hours old.

Storage/Transport Temperature

Room temperature

Stability (from collection to initiation)

Room Temperature ≤4 hours

Remarks

If the patient's Hematocrit is >55%, call the Coagulation lab at 41778 and ask for a light blue top tube with an adjusted amount of 3.2% trisodium citrate anticoagulant.

Volume Required

One completely filled 1.8 mL or 2.7 mL light blue top tube

Minimum Required

One completely filled 1.8 mL light blue top tube

Phlebotomy Draw

Yes

Performing Lab

Coagulation Laboratory

Performed

24/7

Methodology

Mechanical clot detection

Reported

Stat - < 60 Min; Routine - approximately 90 Min

Synonyms

  • PT

LIS Mnemonic

PTI

Available STAT

Yes

Reflex Testing

N/A

Vendor

None

Reference Ranges

>6 months 11.1-13.4 sec
 
For patients < 6 months:
Values change rapidly in the neonatal period and are dependent on the gestational age at delivery.
 Consult Nathan D, Oski F, Hematology of Infancy and Childhood.

CPT Codes

85610
Collection

Collect

Collect in light blue top tubes (sodium citrate anticoagulant).
All routine coagulation testing (PT/INR, PTT, FIB, D-Dimer, Xa-Lovenox, Xa-Unfractionated, DTIBI, ATIII) may be collected in the same tube.

One FULL 1.8 mL OR 2.7 mL tube.











 


Note: For all coagulation testing, ensure tubes are sufficiently filled. Refer to the guide below.

Unacceptable Conditions

Inadequately filled specimens; hemolyzed/clotted specimens; specimens greater than 4 hours old.

Storage/Transport Temperature

Room temperature

Stability (from collection to initiation)

Room Temperature ≤4 hours

Remarks

If the patient's Hematocrit is >55%, call the Coagulation lab at 41778 and ask for a light blue top tube with an adjusted amount of 3.2% trisodium citrate anticoagulant.

Volume Required

One completely filled 1.8 mL or 2.7 mL light blue top tube

Minimum Required

One completely filled 1.8 mL light blue top tube

Phlebotomy Draw

Yes
Ordering

Performing Lab

Coagulation Laboratory

Performed

24/7

Methodology

Mechanical clot detection

Reported

Stat - < 60 Min; Routine - approximately 90 Min

Synonyms

  • PT

LIS Mnemonic

PTI

Available STAT

Yes

Reflex Testing

N/A

Vendor

None
Result Interpretation

Reference Ranges

>6 months 11.1-13.4 sec
 
For patients < 6 months:
Values change rapidly in the neonatal period and are dependent on the gestational age at delivery.
 Consult Nathan D, Oski F, Hematology of Infancy and Childhood.
Administrative

CPT Codes

85610