Test Mnemonic

GLUTEN

Patient Preparation

Multiple patient encounters should be avoided.

Collect

Serum separator tube.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.5 mL serum to an ARUP Standard Transport Tube. (Min: 0.25 mL). For multiple allergen orders refer to "Allergen Specimen Collection Instructions" at www.aruplab.com/testing/resources/specimen.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Referral Lab

Performed

Sun-Sat

Reported

1-3 days

Performing Lab

ARUP Laboratories

CPT Codes

86003

Compliance & Service Center Alerts

ARUP Test ID: 99569

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Additional Technical Information

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

Ordering / Collection

Test Mnemonic

GLUTEN

Patient Preparation

Multiple patient encounters should be avoided.

Collect

Serum separator tube.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.5 mL serum to an ARUP Standard Transport Tube. (Min: 0.25 mL). For multiple allergen orders refer to "Allergen Specimen Collection Instructions" at www.aruplab.com/testing/resources/specimen.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Referral Lab

Test Performance / Compliance

Performed

Sun-Sat

Reported

1-3 days

Performing Lab

ARUP Laboratories

CPT Codes

86003

Compliance & Service Center Alerts

ARUP Test ID: 99569

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Additional Technical Information

Clinical Information

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

Internal Lab Use Only

ARUP Consult®

Disease Topics